Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
equipment:multiphoton:start [2019/08/01 11:20] – [How Tos] jefferisequipment:multiphoton:start [2024/04/18 05:45] (current) – [How Tos] jefferis
Line 1: Line 1:
 ====== Hardware ====== ====== Hardware ======
-We currently have one multiphoton system based around a Sutter MOM core assembled and accessorised by Alex.  Software control is by ScanImage running under Matlab on a PC, communicating via NI DAQ board.  See: +We currently have one multiphoton system based around a Sutter MOM core assembled and accessorised by Alex. This has been modified, moved, and upgraded by Bruno Pichler's company (INSS) and Istvan.  Software control is by ScanImage running under Matlab on a PC, communicating via NI DAQ board.  See: 
-  * [[alex:projects:multiphoton:start|Alex's two-photon project page]] for details for of the hardware setup of 2P number 1 (The 2P furthest from the confocal).+  * [[Hardware details after move to 3N390]] 
 +  * [[alex:projects:multiphoton:start|Alex's two-photon project page]] - obsolete.
   * [[NI Board Connections]]   * [[NI Board Connections]]
   * [[objective mount]]   * [[objective mount]]
Line 19: Line 20:
   * [[Basic use of 2p system]] (copied over from PC Desktop in first instance)   * [[Basic use of 2p system]] (copied over from PC Desktop in first instance)
   * [[imaging_2p|Detailed step by step use of 2p system]]   * [[imaging_2p|Detailed step by step use of 2p system]]
-  * [[2P Risk Assessment]] 
   * [[protocols:Aligning the 2p laser]]   * [[protocols:Aligning the 2p laser]]
   * [[http://research.janelia.org/wiki/display/ephus/ScanImage%2C+Ephus%2C+and+other+DAQ+software|ScanImage Docs]] and [[http://www.neuroptikon.org/projects/display/ephus/ScanImage+Matlab+and+NI+Version+Compatibility|Matlab Compatibility matrix]]   * [[http://research.janelia.org/wiki/display/ephus/ScanImage%2C+Ephus%2C+and+other+DAQ+software|ScanImage Docs]] and [[http://www.neuroptikon.org/projects/display/ephus/ScanImage+Matlab+and+NI+Version+Compatibility|Matlab Compatibility matrix]]
Line 31: Line 31:
   * [[aaron:projects:excitation_of_alexa_dyes_and_fps|Excitation Wavelengths for dyes and fluorescent proteins]]   * [[aaron:projects:excitation_of_alexa_dyes_and_fps|Excitation Wavelengths for dyes and fluorescent proteins]]
   * [[Change Coolant for Laser]]   * [[Change Coolant for Laser]]
 +  * [[2P Dissections]] 
 +  * [[https://www.biorxiv.org/content/10.1101/2024.01.23.576417v1|Packer Multiphoton Testing Protocols]]
 ====== Safety ====== ====== Safety ======
  
 See also the general lab [[safety:start|Safety page]] See also the general lab [[safety:start|Safety page]]
  
-  * Class IV Laser Safety RA +  * [[2P Risk Assessment]] 
-  * Standard Operating Procedures+  * Class IV Laser Safety RA {{ :equipment:multiphoton:ra_sutter_movable_objective_multiphoton_microscope.docx |}} 
 +  * Standard Operating Procedures {{ :equipment:multiphoton:sutter_movable_objective_microscope_sop_normal_and_alignment_use.pdf |}}
 ====== Maintenance ====== ====== Maintenance ======
   * We have a 3 year extended warranty with Coherent until 18th March 2014 - {{:equipment:multiphoton:coherentmaintenance2011-2014.pdf|details in this pdf}}   * We have a 3 year extended warranty with Coherent until 18th March 2014 - {{:equipment:multiphoton:coherentmaintenance2011-2014.pdf|details in this pdf}}
   *  Contact at Coherent is Mike Shearer (mike.shearer@coherent.com - Tel: 01353 65 88 54)   *  Contact at Coherent is Mike Shearer (mike.shearer@coherent.com - Tel: 01353 65 88 54)
  

Log In